Promag 53L

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Features and specifications

Back

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    The flowmeter with a weight‐optimized sensor and flexible system integration. Fully suitable for standard applications in the water and wastewater industry.

  • Sensor features

    Reduced installation costs – flexible mounting by one‐of‐a‐kind lap‐joint flange concept (DN <350/14"). Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Up to 30 % less sensor weight. Nominal diameter: DN 25 to 2400 (1 to 90").

  • Transmitter features

    Quality – software for filling & dosing, density, electrode cleaning and also advanced diagnostics. Easy calculation – bidirectional totalizers. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote Version.

  • Nominal diameter range

    Lap joint flange; lap joint flange, stamped plate: DN 25 to 300 (1 to 12")
    Fixed flange: DN 350 to 2400 (14 to 90")

  • Wetted materials

    Liner: PTFE; Polyurethane; Hard rubber
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

  • Measured variables

    Volume flow, mass flow

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
    Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

    9 dm³/min to 162 000 m³/h (2.5 gal/min to 1030 Mgal/d)

  • Max. process pressure

    PN 16, Class 150

  • Medium temperature range

    Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
    Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
    Liner material PTFE: –20 to +90 °C (–4 to +194 °F)

  • Ambient temperature range

    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    DN 25 to 300 (1 to 12"): AlSi10Mg, coated
    DN 350 to 2400 (14 to 90"): Carbon steel with protective varnish
    Sensor connection housing: AlSi10Mg, coated

  • Transmitter housing material

    A: Powder‐coated die‐cast aluminum

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version (standard): IP66/67, type 4X enclosure
    Sensor remote version (option): IP68, type 6P enclosure
    Transmitter remote version: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency (passive)
    Relay output
    Switch output (passive)

  • Inputs

    2 modular inputs:
    Status input
    0‐20 mA (aktiv)/4‐20 mA (aktiv/passiv)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, MODBUS RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    cCSAus

  • Product safety

    CE, C-tick

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025),

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • F
  • 7
  • B
    • Nr B Order code 50106085

      Kit meas. amplifier PMAG 53 WEA

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039454

      Kit meas. amplifier 53 WEA HE

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106087

      Kit meas. amplifier PMAG 53 SEA

      Language: JA, ID, EN

    • Nr B Order code 71039456

      Kit meas. amplifier 53 SEA HE

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106086

      Kit meas. amplifier PMAG 53 EES

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039455

      Kit meas. amplifier 53 EES HE

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50108133

      Kit meas. amplifier Pmag 53 CN

      CN= language ZH + EN

    • Nr B Order code 71039457

      Kit meas. amplifier 53 CN HE

      Language: ZH, EN HE = harsh environment

    • Nr B Order code 71261680

      Kit amp. 53, HART7, DE+FR+IT+ES+EN

      Language: DE+FR+IT+ES+EN

    • Nr B Order code 71261682

      Kit amp. 53, HART7, DE+FR+IT+ES+EN, HE

      Language: DE+FR+IT+ES+EN HE = harsh environment

    • Nr B Order code 71261686

      Kit amp. 53, HART7, RU+NL+PT+CS+EN

      Language: RU+NL+PT+CS+EN

    • Nr B Order code 71261687

      Kit amp. 53, HART7, RU+NL+PT+CS+EN, HE

      Language: RU+NL+PT+CS+EN HE = harsh environment

    • Nr B Order code 71261690

      Kit amp. 53, HART7, ZH+PL+ID+EN

      Language: ZH+PL+ID+EN

    • Nr B Order code 71261692

      Kit amp. 53, HART7, ZH+PL+ID+EN, HE

      Language: ZH+PL+ID+EN HE = harsh environment

    • Nr B Order code 71261693

      Kit amp. 53, HART7, JA+SV+NO+FI+EN

      Language: JA+SV+NO+FI+EN

    • Nr B Order code 71261694

      Kit amp. 53, HART7, JA+SV+NO+FI+EN, HE

      Language: JA+SV+NO+FI+EN HE = harsh environment

  • C
  • D
    • Nr D Order code 71021743

      Kit Com ModbusRS485+stat.In 2Interf.Ex

      53/83/84/65/8CN/8DF

    • Nr D Order code 71039485

      Kit I/O Modb.RS485+Stat.In 2Interf.HE EX

      53/83/84/8CN/8DF HE = Harsh environment

    • Nr D Order code 50108002

      Kit I/O Profib. DP+Stat.In 2 Interf. Ex

      53/55/83/93

    • Nr D Order code 71039486

      Kit I/O Profib.DP+Stat.In 2 Interf.HE EX

      53/55/83 HE = harsh environment

    • Nr D Order code 50096833

      Kit Commodul current out 3 Interface Ex

      53/55/8X/93/65

    • Nr D Order code 71039477

      Kit I/O current out 3 Interface HE EX

      53/55/8X HE = harsh environment

    • Nr D Order code 71105712

      Kit I/O Modul 53/83 Ethernet

      Including Subprint Ethernet

  • 2
  • 3
  • 4
  • 5
  • 6
  • 37
  • J
    • Nr J Order code 50096755

      Kit display modul Wall enclosure

      53/55/83/84/93/8CN/8DF

  • E
  • 21
  • G
  • 19
  • 18
  • A
    • Nr A Order code 50098018

      Kit connection board D/E/L/P/S/W FS

      Usage: 10/50/51/53/55/400/800

    • Nr A Order code 71039497

      Kit connection board D/E/L/P/S/W FS HE

      Usage: 10/50/53/55 HE = harsh environment

  • 29
  • 30
  • 1
  • S
    • Nr S Order code 71003948

      Kit S-Dat Promag 53 programmed

      Serialnumber is forceful required

  • 8
  • 9
  • 10
    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

  • 26
    • Nr 26 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 26 Order code 71247838

      Repair kit cover, remote version

      Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease

  • 15
  • 12
  • 14
  • 13
  • 20
  • 11
  • 22
    • Nr 22 Order code 50098020

      Kit parts housing compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W

  • 24
    • Nr 24 Order code 50098019

      Kit parts housing FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W

  • 25
    • Nr 25 Order code 50098023

      Kit housing gasket FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W

  • 23
    • Nr 23 Order code 50098024

      Kit housing gasket compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W

    • Order code DK5CA-

      Promag, cable remote version

      10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable

    • Order code 53XXX-

      Promag 53, transmitter

    • Order code DK5WM-

      Transmitter Promag, mounting set

      10/50/51/53/55/800

    • Order code DK5UI-

      Promag 53, retro fit kit In/Output

      A retrofit kit consists of an instruction sheet, meter documentation, retrofit label, connection label and the exchangeable I/O modules.

    • Order code DK5SO-

      Promag 53/55, software package

      Chip for release of software functionality. Note: The license is locked to a specific serial number (S-DAT).

    • Order code DK5GC-

      Promag L/W/P/S,E, grounding cable kit

      A kit includes 2 cables

    • Order code DK5GD-

      Promag, grounding disc/protection disc

      Includes 1 grounding disc/protection disc

    • Order code FXA193-

      Serviceinterface FXA193

      The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.

  • Successor