Proline Promag D 400
Electromagnetic flowmeter
Wafer flowmeter for the water and wastewater industry
The wafer flowmeter Promag D is designed for all basic water applications where space is at a minimum. Its innovative housing construction enables a customized and fast centering as well as a cost-optimized installation. Promag D 400 saves time and costs thanks to the broad functionality of its water- and wastewater-optimized transmitter. In addition, Heartbeat Technology ensures measurement reliability and compliant verification.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
9 to 4700 dm³/min (2.5 to 1250 gal/min)
-
Medium temperature range
0 to +60 °C (+32 to +140 °F)
-
Max. process pressure
PN 16, Class 150, 10K
-
Wetted materials
Liner: Polyamide
Electrodes: 1.4435 (316L)
-
Quick selection
Individual configuration
-
Benefits
Easy, fast centering of the sensor – innovative housing construction
Energy-saving flow measurement – no pressure loss due to cross section constriction
Maintenance-free – no moving parts
Safe operation – no need to open the device due to display with...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
For basic water applications; optimized for limited space and plastic pipe installations
Device properties
Short installation length and...
Documents / Manuals / Software
-
Proline Promag D 400
Technical Information
Electromagnetic flowmeter
Meter designed as compact wafer version with a state‐of‐the‐art transmit
ter for Water & WastewaterTechnical Information (TI) -
Proline Promag D 400
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag D 400
Modbus RS485
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag D 400
EtherNet/IP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag D 400
PROFIBUS DP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 400
PROFIBUS DP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 400
EtherNet/IP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 400
Modbus RS485
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 400
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag D 400
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)09/15English -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17English -
Proline Promag D
Brief Operating Instructions
Proline Promag D
Electromagnetic sensorShort Instruction (KA)03/17English -
Flow device
Proline 400
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flow device
Proline 400
Brief Operating Instructions
HART transmitter
with electromagnetic sensorShort Instruction (KA)02/19English -
Flow device
Proline 400
Brief Operating Instructions
Modbus RS485 transmitter
with electromagnetic sensorShort Instruction (KA)02/19English -
Flow device
Proline 400
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Replacing Small Parts
Promag 400 , Promag 800 Index B, Cubemass, Promag 500, Promag, Promass,
Prosonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Replacing connection board electronics compact and remote
Promag 400 Index C
Installation Instructions (EA) -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Installation Instructions (EA) -
Pipe Mounting Set
Installation Instructions
Promag 400 Index C
Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Repair kit cover remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65Installation Instructions (EA) -
Replacing the electronics
Promag 400 Index C
Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Interface parts
Installation Instructions
Promag 10, 23, 50, 51, 53, 55, 400, 800
Installation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the Display module
Promag 400 Index C
Installation Instructions (EA) -
Replacing the transmitter
Promag 400 Index C
Installation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Replacing the Display Protection
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing the Components for the Transmitter
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing Sensor parts remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN,
CNGmass 8DFInstallation Instructions (EA) -
Replacing the sensor
Promag 400 Index C
Installation Instructions (EA) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline Promag 400
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
PROFIBUS DP
Acyclic data transfer
Special Documentation
Transmitter terminal assignment
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag 400
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
Register information Modbus RS485
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 400
HART
Heartbeat Verification + Monitoring application package
Special Documentation (SD) -
Proline Promag 400
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 400 HART: 1.05.02Manufacturer Information (MI) -
Proline Promag 400
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 400 PROFIBUS DP: 1.01.00Manufacturer Information (MI) -
Proline Promag 400
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 400 EtherNet/IP: 1.01.02Manufacturer Information (MI) -
Proline Promag 400
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 400 HART: 2.01.00Manufacturer Information (MI) -
Proline Promag 400
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 400 HART: 2.00.01Manufacturer Information (MI) -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17English -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17German -
Proline Promag 400
Misure di portata per acque potabili e reflue
Innovations (IN)11/19Italian -
Proline Promag 400
For flow measurement of water and wastewater
Innovations (IN)11/19English -
Proline Promag 400
Für die Durchflussmessung von Wasser und Abwasser
Innovations (IN)11/19German -
Ethernet industriel pour débitmètres Proline
L'intégration système du futur
Innovations (IN)10/15fr -
Proline Promag 400
Pour la mesure de débit sur l'eau et les eaux usées
Innovations (IN)04/19fr -
Promag D400
Magnetisch-induktives Durchflussmessgerät zur bidirektionalen Messung
von
Flüssigkeiten mit einer Mindestleitfähigkeit von ≥ 5 μS/cm.Tender Text06/20German -
Promag D400
Electromagnetic flowmeter, microprocessor based and self checking,
compact versionTender Text06/16English -
GSD Single, GSD_DP_FL_Promag400_0x1562_0x02_0x01, 11.05.2017 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promag400_0x1562_0x01_0x01, 27.04.2015 (Flow, Proma
g 400, 0x1562)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_400_0x1047_0x02_0x01, 23.10.2015 (Flow, Promag 400)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)2.1Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_400_0x1047_0x01_0x01, 23.10.2015 (Flow, Promag 400)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.1Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x0067_0x05_0x01, 31.03.2014 (Flow, Promag 400, 0x0067)
HART,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, AMS11_HART_FL_Promag400_0x0067_0x06_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x1169_0x08_0x01, 22.11.2018 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x0067_0x06_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag400_0x1562_0x01_0x01, 22.02.2019 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag400_0x1169_0x09_0x01, 04.05.2020 (Flow, Promag 400, 0x1169)
HART,
Experion Version: R511
Field Device Manager Version: R511Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_FL_Promag400_0x1169_0x08_0x01, 22.11.2018 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag400_0x0067_0x05_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x0067_0x05_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x1169_0x09_0x01, 08.05.2020 (Flow, Promag 400, 0x1169)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag400_0x1562_0x02_0x01, 11.05.2017 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
PDM Version: 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag400_0x1169_0x09_0x01, 05.05.2020 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x1169_0x09_0x01, 05.05.2020 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0, 14.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x0067_0x06_0x01, 16.03.2015 (Flow, Promag 400, 0x0067)
HART,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag400_0x0067_0x06_0x01, 16.03.2015 (Flow, Promag 400, 0x0067)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag400_0x1169_0x08_0x01, 20.03.2017 (Flow, Promag 400, 0x1169)
HART,
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x1169_0x08_0x01, 20.03.2017 (Flow, Promag 400, 0x1169)
HART,
PDM Version: 6.1, 8.2.1, 9.0.1Electronic Data Description (EDD)1.00Language neutral -
DTM Single, Promag400_5x4C_HART_FW2_00_zz_Dev_Rev_8, 27.10.2020 (Flow, Promag 400, 0x1169)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4Device Type Manager (DTM)1.9.0.191Language neutral -
DTM Single, Promag400_5x4C_DP_FW1_01_zz_Dev_Rev_2, 06.11.2020 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
ABB 800xA Control Builder M Version: 5.1 and newer
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Freelance (Control Builder F) Version: 2013 V10.1.8311
PACTware Version: 4.1
S+ Composer Melody Version: 6.1 and newerDevice Type Manager (DTM)1.8.0.58Language neutral -
DTM Single, Promag_400_5x4C_EIP_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 400, 0x1067)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.8.0.101Language neutral -
DTM Single, Promag_400_5x4C_MR4_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 400)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.0.59Language neutral -
DTM Single, Promag_400_5x4C_MR4-CDIE_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 400, 0x6447)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.0.59Language neutral -
DTM Single, Promag400_5x4C_HART_FW2_01_zz_Dev_Rev_9, 27.10.2020 (Flow, Promag 400, 0x1169)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4Device Type Manager (DTM)1.39.0.276Language neutral -
DTM Single, Promag_400_5x4C_EIP-CDIE_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 400, 0x1067)
EtherNet/IP,
DeviceCare Version: 1.04.00, 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.12.00, 2.15.00Device Type Manager (DTM)1.3.0.84Language neutral -
DTM Single, Promag_400_5x4Cxx_EIP_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promag 400, 0x1067)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.3.0.61Language neutral -
DTM Single, Promag_400_5x4C_DP_FW_1_00_zz_Dev_Rev_1, 19.10.2020 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.3.0.28Language neutral -
DTM Single, Promag400_5x4C_HART_FW1_05_zz_Dev_Rev_6, 27.10.2020 (Flow, Promag 400, 0x0067)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.3.0.132Language neutral -
DTM Single, Promag_400_5x4C_MR4-CDIE_FW_2_00_zz_Dev_Rev_04, 06.11.2020 (Flow, Promag 400, 0x6469)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.148Language neutral -
DTM Single, Promag_400_5x4C_MR4_FW_2_00_zz_Dev_Rev_04, 06.11.2020 (Flow, Promag 400, 0x6469)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.148Language neutral -
DTM Single, Promag400_5x4Cxx_HART_FW1_04_zz_Dev_Rev_5, 26.10.2020 (Flow, Promag 400, 0x0067)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.0.0.32Language neutral -
AOP Single, RS_EIP_FL_Promag400_5x4C_0x1067_0x02_0x01, 20.11.2018 (Flow, Promag 400, 0x1067)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.65.01Language neutral -
AOP Single, RS_EIP_FL_Promag400_5x4C_0x1067_0x01_0x01, 20.11.2018 (Flow, Promag 400, 0x1067)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.65.01Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag400_0x1169_0x08_0x01, 20.03.2017 (Flow, Promag 400, 0x1169)
HART,
Plant Resource Manager Version: R3.30Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag400_0x0067_0x06_0x01, 16.03.2015 (Flow, Promag 400, 0x0067)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag400_0x0067_0x05_0x01, 31.03.2014 (Flo
w, Promag 400, 0x0067)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Promag D, Promag L, Promag W
Product Code: 5D4B-, 5D4C-, 5L4B-, 5L4C-, 5W4B-, 5W4C-
Declaration Number: EC_00276_02.16EU DeclarationGerman , English , fr -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
t-mass T, Prowirl R, Prowirl O, Prowirl F, T-MASS I, T-MASS F, t-mass B, t-mass A, t-mass, Prowirl D, PROSONIC FLOW P, Prosonic Flow G, PROSONIC FLOW E, Prosonic Flow 93, Prosonic Flow B, Prosonic Flow 92, Prosonic Flow 91, PICOMAG, Magphant, Dosimass, Promass 40, Promag D
Product Code: 92F-, ODMA-, 7R2B-, 7F2B-, 93P-, 93W-, 7O2B-, 7D2B-, 7O2C-, 7F2C-, 7R2C-, 65I-, 93C-, 7D2C-, 65F-, 93TA1-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9P5B-, DMA-, DTI200-, DTT31-, DTT35-, DTT35L-, DTT31L-, 91W-, 8E-, 6TAB-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 5D4C-, 40E-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EACE N RU-D.CH.AD07.B.02246/20MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Promag D, Promag L, Promag W
Product Code: O5W4C-, O5W4B-, O5L4C-, O5L4B-, O5D4C-, O5D4B-, 5W4C-, 5W4B-, 5L4C-, 5L4B-, 5D4C-, 5D4B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D T4
Protection: NIExplosion ProtectionEnglish -
Promag D, Promag L, Promag W
Product Code: 5L4B-, 5D4C-, 5D4B-, O5W4C-, O5W4B-, O5L4C-, O5L4B-, O5D4C-, O5D4B-, 5W4C-, 5W4B-, 5L4C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D T4
Protection: NIExplosion ProtectionEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag L, Promag P, Promag W
Product Code: 5L4B-, 5L4C-, 5L8B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5P1B-, O5P2B-, O5W1B-, 10D-, 10L-, 10P-, 10W-, 50D-, 50L-, 50P-, 50W-, 51P-, 51W-, 53P-, 53W-, 5D4B-, 5D4C-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag D
Product Code: 10D-, 50D-, 5D4B-, 5D4C-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag W, Promag L, Promag D
Product Code: 5D4C-, 5W4C-, 5L4C-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0.2Fieldbus ConformanceEnglish -
Promag D, Promag L, Promag W
Product Code: 5D4C-, 5L4C-, 5W4C-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 02.00.01Fieldbus ConformanceEnglish -
Promag D, Promag W, Promag L
Product Code: 5D4C-, 5W4C-, 5L4C-
Region/Country: International
Approval Agency: ODVA
Software Version: MAJOR REV. 02, MINOR REV. 01Fieldbus ConformanceEnglish -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Promag D, Promag P, Promag W, Promag H, Promag L, Promag E
Product Code: 5W8B-, 5W4C-, 5L4C-, 5P1B-, 5H1B-, 5H3B-, 5E1B-, 5P2B-, 5D4C-, 5H2B-, 5W4B-, 5L4B-, 5E2B-, 5D4B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.А NO. 59660/1MetrologyRussian -
Promag D, Promag L, Promag W
Product Code: 5D4C-, 5L4C-, 5W4C-
Region/Country: Germany
Approval Agency: TÜVRadiation ProtectionGerman , English
Accessories / Spare parts
-
-
Nr 45 Order code 71228789
Kit connection terminals, Promag 400(C)
(C) = generation index C. Consists of: Connection terminal 3-Pol stamp 1,2, Connection terminal 2-Pol stamp A,B, Connection terminal 4-Pol stamp 20-23, Connection terminal 4-Pol stamp 24-26.
-
-
-
Nr 40 Order code 71228791
Kit connec. board, D, compact, electr.
Usage: Promag 400(C) with sensor D. (C) = generation index C.
-
Nr 40 Order code 71228790
Kit connec. board, D/L/W, remote,electr.
Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C.
-
-
-
Nr 30 Order code XPD0014-
Electronic Promag 400 Index C
Complete main electronic module or power supply, I/O-board and amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection/ Amplifier incl. ribbon cable.
-
-
-
Nr 44 Order code 50098018
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 30 Order code XPD0040-
Electronic Promag 400 Index C update
Complete main electronic module or power supply, I/O-board with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection and Amplifier incl. ribbon cable.
-
-
-
Nr 50 Order code XPD0017-
-
-
-
Nr 20 Order code 71443262
Kit cover, polycarbonate, 400(C), v1+v2
Usage: Promag 400 (C) (C) = generation index C. Consists of: Version 1: cover polycarbonate complete, 2x hinge pin L= 58mm plastic. Version 2: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, wire with screw lock 1,5x150.
-
Nr 20 Order code 71384170
Kit cover, alu,Promag 400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
-
-
Nr 24 Order code 50094038
-
Nr 24 Order code 71247838
Repair kit cover, remote version
Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease
-
-
-
Nr 25 Order code 71278077
Kit 10 cover gasket, polycarbonate
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.
-
Nr 25 Order code 71278078
Kit cover gasket, alu,400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.
-
-
-
Nr 71 Order code 71228793
Kit housing gasket, D/L/W,compact,400(C)
Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: Gasket EPDM for housing/sensor D/L/W. O-Ring 29,87x1,78 HNBR for sensor- plug L/W.
-
-
-
Nr 73 Order code 50098023
Kit housing gasket FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W
-
-
-
Nr 12 Order code 71228794
Kit housing parts, D/L/W, compact,400(C)
Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: 4x screw M5x18 hex cap DIN912 pla, 4x spring washer M5 DIN7980 st.pla, for housing/sensor.
-
-
-
Nr 13 Order code 50098019
Kit parts housing FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
-
-
Nr 17 Order code 50096840
Kit 10 cable glands M20x1,5
-
-
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
-
-
Nr 17 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
-
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
-
-
Nr 17 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
-
-
Nr 82 Order code 71228792
Kit display protec., 400(C)/500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.
-
-
-
Order code 5X4CXX-
Transmitter/Conversion Kit Promag 400
Same housing for compact/remote version. Corrosion-resistant transmitter version. With an integrated web server Conversion kit: For conversion of an already existing Promag to the new device generation or to another device version. Consists of all required conversion parts.
-
Order code DK5005-
-
Order code DK5CA-
Promag, cable remote version
10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable
-
Order code DK5DD-
-
Order code DKD-
Promag D, mounting set
The mounting set contains threaded bolts, centering sleeves, nuts, washers and a pair of EPDM flange seals orderable separately, as replacement for M1, M2
-
Order code XPRFID-
-
-
Predecessor