Enter at least 2 characters to start the search.

Radar measurement
Micropilot FMR60

Micropilot FMR60 ©Endress+Hauser

Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

Unique HistoROM data management concept for safe level measurement

Micropilot FMR60 ©Endress+Hauser

The standard sensor for highest demands in liquid level measurement with 80GHz technology

Micropilot FMR60 is the first 80GHz radar developed according to the international functional safety directive IEC 61508. The free space radar offers maximum reliability due to the drip-off antenna, improved algorithms and small beam angle. It is used for continuous non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. It also possesses the smart sensor functionality Heartbeat Technology.

  • Simple products

  • Easy to select, install and operate

Technical excellence

Simplicity

  • Standard products

  • Reliable, robust and low-maintenance

Technical excellence

Simplicity

  • High-end products

  • Highly functional and convenient

Technical excellence

Simplicity

  • Specialized products

  • Designed for demanding applications

Technical excellence

Simplicity

Variable

FLEX selections Technical excellence Simplicity
  • F
  • L
  • E
  • X

Fundamental selection

Meet your basic measurement needs

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Lean selection

Handle your core processes easily

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Extended selection

Optimize your processes with innovative technologies

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Xpert selection

Master your most challenging applications

Technical excellence
Simplicity

Variable

  • Specs at a glance

    • Accuracy

      +/- 1 mm (0.04 in)

    • Process temperature

      -40…+130 °C
      (-40…+266 °F)

    • Process pressure absolute / max. overpressure limit

      Vacuum …16 bar
      (Vacuum … 232 psi)

    • Max. measurement distance

      50 m (164 ft)

    • Main wetted parts

      PTFE antenna
      PP or 316L process connections

please wait Loading alternative products

Quick selection

Choose from our suggested options
Sales price
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

or

Individual configuration

Continue your selection from all possible options
  • Benefits

    • Hardware and software developed according to IEC 61508 up to SIL3 in homogeneous redundancy

    • Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle

    • HistoROM data management concept for fast and easy commissioning...

  • Field of application

    80GHz drip-off antenna suited for free space applications up to 50m and offers high beam focusing for vessels with many internal fittings.

    • Process connections: Threads or flanges

    • Temperature: –40 to +130°C (–40 to +266°F)

    • Pressure: –1 to +16bar (–14.5...

Features and specifications

Back

Details

  • Measuring principle

    Level radar

  • Characteristic / Application

    For basic level measurement in liquids, pastes and slurries;

    non affected by changing media, temperature changes, gas blankets or vapor;

    For applications with many obstacles due to the very small beam angle.

  • Specialities

    Heartbeat Technology,

    SIL 2/3 according to IEC 61508,

    Bluetooth® commissioning,

    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi-Echo Tracking

    HistoROM

    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART)

    Bluetooth® wireless technology and App (optional)

  • Frequency

    W-band (~80 GHz)

  • Accuracy

    +/- 1 mm (0.04 in)

  • Ambient temperature

    -40…+80 °C

    (-40…+176 °F)

  • Process temperature

    -40…+130 °C

    (-40…+266 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum …16 bar

    (Vacuum … 232 psi)

  • Main wetted parts

    PTFE antenna

    PP or 316L process connections

  • Process connection

    Thread:

    G1-1/2", MNPT1-1/2";


    Flange:

    UNI DN80…DN150 (3"…6")

  • Max. measurement distance

    50 m (164 ft)

  • Communication

    4…20 mA HART,

    Additional switch,

    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, JPN Ex

  • Safety approvals

    Overfill protection WHG

    SIL 2, SIL 3

  • Design approvals

    EN 10204-3.1

  • Options

    Display,

    Customized parameterization,

    Remote operation via SmartBlue App using Bluetooth®,

    Gas-tight feed through,

    PWIS free

  • Application limits

    Process temp. > 130 °C (266 °F) -> FMR62

    Very aggressive media -> FMR62

    Strong turbulences and foam, stilling well and bypass -> FMR5x, FMP5x

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • 19
    • Nr 19 Order code 71115175

      Housing filter Brass/Ni GT19/20, 1 set

      Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 17
    • Nr 17 Order code 71115176

      Set housing securing clamps

      Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 20
    • Nr 20 Order code 71110292

      Cover GT19 PBT, sight glass, EPDM

      Material: plastics PBT-FR sight glas PC. O-ring EPDM, PTFE coated. Usage: FHX50, FMP50/FMP51/FMP52/ FMP53/FMP54/FMP55/FMP56/FMP57, FMR50/ FMR51/FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 20 Order code 71110293

      Cover GT19 PBT, EPDM

      Material: plastics PBT, metallized. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

  • 25
    • Nr 25 Order code 71110295

      Cover GT19 PBT, Terminal Ex, EPDM

      Material: plastics PBT, metallized. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Nr 25 Order code 71185518

      Cover GT19 PBT, Terminal, OVP, EPDM

      Material: plastic PBT, metallizied. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Order code 71450381

      Plug M12, IP66/68 NEMA4X/6P, ProToF

      For electrical connection. Usage: FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR57, FMR60/FMR62/FMR67.

  • 20
    • Nr 20 Order code 71110297

      Cover GT20 Alu, sight glass, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 20 Order code 71110299

      Cover GT20 Alu, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 25
    • Nr 25 Order code 71110301

      Cover GT20 Alu, Terminal Ex, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71110302

      Cover GT20 Alu, Terminal Ex d, HNBR

      Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Nr 25 Order code 71185517

      Cover GT20 Alu, Terminal, OVP, HNBR

      Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 65
    • Nr 65 Order code 71110303

      Sealing set GT18/GT19/GT20, EPDM, HNBR

      Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128617

      Overvoltage protection (OVP10),1-Channel

      4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code 71128619

      Overvoltage protection (OVP20),2-Channel

      4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 34
    • Nr 34 Order code 71350681

      I/O module 2-wire, 4-20mA, HART, Ex, V3

      Non-Ex, Ex. 1x current output HART. Version 3. Usage: FMR60/FMR62/FMR67.

    • Nr 34 Order code 71350683

      I/O module,2-wr., 4-20mA,HART,PFS, Ex V2

      Non-Ex, Ex. 1x current output HART, 1x PFS. PFS=switch output. Version 2. Usage: FMR60/FMR62/FMR67.

    • Nr 34 Order code 71350687

      I/O mod. Level, 2-wr.2x4-20mA,HART,Ex,V3

      Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Version 3. Usage: FMR60/FMR62/FMR67.

    • Nr 34 Order code 71364026

      I/O mod.Level,2-wr.4-20mA,HART,Ex,LP,V3

      Version 3. Not for Ex d/XP. LP=low powered. 1x current output HART. Usage: FMR60/FMR62/FMR67.

  • 37
    • Nr 37 Order code 71110280

      Terminal set 2-wire, I/O module

      Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

  • 40
    • Nr 40 Order code 71248380

      Spare parts set - retrofit kit FHX50

      Consists of: transmitter board, ribbon cable, cable gland, M12 bushing, VA. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.

  • 40
    • Nr 40 Order code 71206552

      Cable FHX50, 5m

      Connection cable, shielded. Usage: FHX50.

    • Nr 40 Order code 71206554

      Cable FHX50, 10m

      Connection cable, shielded. Usage: FHX50.

    • Nr 40 Order code 71206555

      Cable FHX50, 20m

      Connection cable, shielded. Usage: FHX50.

    • Nr 40 Order code 71206556

      Cable FHX50, 30m

      Connection cable, shielded. Usage: FHX50.

  • 30
    • Nr 30 Order code XPF0038-

      Electronics Micropilot FMR6x

      Usage: FMR60/FMR62/FMR67.

  • 40
    • Nr 40 Order code XPD0024-

      Display module, SD02, push buttons

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.

    • Nr 40 Order code XPD0025-

      Display module, SD03, Touch Control

      For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.

    • Order code 71377355

      Bluetooth module (BT10)

      Module for wireless data communication. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.

    • Order code 71336522

      Mounting bracket, FMR60/67

      Material: 304. Usage: alignment FMR60/FMR67.

    • Order code 71162242

      Weather prot. cover GT18/GT19/GT20, 316L

      Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

  • 57
    • Nr 57 Order code 52014047

      Sealing ring G1-1/2, 48x55 FA, 5 pcs.

      Process gasket DIN7603-A. Usage: process connection, FMI21, FMI51/FMI52, FTI51/FTI52, FTI55, FTW31/FTW32, FMP51/FMP57, FMR60/FMR62/FMR67, Sliding sleeve G1-1/2 316L (52003665), 316L,3.1 (52011882), FTL51, FTL71,FTL81, AlloyC4 (52003666), FTL51, FTL71.