Specs at a glance
-
Measuring range
k=0,1: 0,04 to 500 µS/cm
-
Process temperature
-5 to 120 °C (23 to 248 °F)
For Sterilizsation: max. 150 °C at 5 bar
(Max. 302 °F at 73 psi) -
Process pressure
13 bar at 20 °C (188 psi at 68 °F)
9 bar at 120 °C (130 psi at 248 °F)
Field of application
Memosens CLS16E is a high-end conductivity sensor with certified hygienic design conforming to FDA and USP Class VI. It measures with highest precision delivering reliable data for optimum process and product quality. The sensor is robust and offers a long operating life thanks to its replaceable seal. With Memosens 2.0 technology, CLS16E is able to store more calibration and process data, facilitating predictive maintenance and providing the perfect basis for IIoT services.
Memosens CLS16E measures conductivity in pure and ultrapure water applications for the monitoring and control of:
Water for injection (WFI)
Electro-deionizing
Ion exchangers
Reverse osmosis
Distillation
With its international explosion protection approvals, such as ATEX, FM, CSA and NEPSI, the digital sensor is suitable for hazardous area use.
Benefits
Certified with quality certificate and EN 10204 3.1 and complying with EHEDG, USP Class VI, ASME and FDA, Memosens CLS16E is perfectly suited for hygienic applications in the life sciences and food industries.
The sensor is sterilizable and autoclavable, resists cleaning in place (CIP) and sterilization in place (SIP).
Stainless steel ensures robust, corrosion-free operation and the replaceable seal enables a long operating life.
Highest precision and measuring accuracy even at high temperatures and under pressure provide you with reliable data for optimum process and product quality.
Non-contact, inductive signal transmission ensures high process integrity.
IIoT ready: Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Videos
-
The conductivity of a liquid can be measured using the conductive or toroidal measuring principles. This video shows what it is about and how these measuring principles work.
-
Memosens converts the measured value to a digital signal and transfers it to the transmitter without a contacting connection. This video shows how Memosens optimizes process control and maintenance.
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Conductive
-
Application
Pure and ultrapure water
Pharmaceutical industry
Final rinse
WFI -
Characteristic
Hygienic 2-electrode conductivity sensor
-
Measuring range
k=0,1: 0,04 to 500 µS/cm
-
Measuring principle
Conductive conductivity cell with electropolished stainless steel electrodes
-
Design
Hygienic 2-electrode conductivity sensor with coaxially arranged electrodes, electropolished
-
Material
n contact with medium
Sensor depending on order execution:
Electropolished, stainless steel 1.4435 (AISI 316L)
PEEK
Sealing depending on order execution:
Form seal ISOLAST (FFKM)
Form seal EPDM -
Dimension
Electrode diameter: 17 mm (0.66 inch)
Electrode length: 54 mm (2.13 inch) -
Process temperature
-5 to 120 °C (23 to 248 °F)
For Sterilizsation: max. 150 °C at 5 bar
(Max. 302 °F at 73 psi) -
Process pressure
13 bar at 20 °C (188 psi at 68 °F)
9 bar at 120 °C (130 psi at 248 °F) -
Temperature sensor
Pt1000
-
Ex certification
ATEX, NEPSI, CSA, IECEx, INMETRO, EAC Ex
-
Connection
Process connection: Varivent, Neumo, BioControl, Clamp
Sensor connection: Inductive, digital connection head with Memosens 2.0 technology -
Ingress protection
IP68
-
Certificates, declarations and approvals
Inspection certificate 3.1, EN10204
Surface roughness test ISO4287/Ra (≤ 0,38 µm)
Conformity to cGMP derived requirements
ASME BPE
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products