

- F
- L
- E
- X
Multi optic calibration and verification kit

- F
- L
- E
- X
Specs at a glance
-
Spectral intensity reference
Calibration Reference Standard
-
Spectral intensity calibration range
CRS-785: 790.7 to 1074.5 nm
Field of application
Raman calibration and verification kits have everything needed to standardize your Raman bioprocess system for lab-to-process scalability. Kits are available for our
Benefits
Uses modular hardware to simplify Raman analyzer standardization and verification, contained in a convenient, all-in-one kit
Facilitates easy calibration transfer of chemometric models for smooth lab-to-process scalability
Offers flexibility to calibrate anytime without impacting your process, which simplifies redundancy and mitigates risk
Enables quick instrument calibration and verification, reducing down time
Requires no external power for easier deployment in the field
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Raman spectroscopy
-
Temperature
Operating:
0 to 40 °C /32 to 104 °F
Storage:
-15 to 50 °C / 5 to 122 °F -
Relative humidity
Storage:
< 80 % Non-Condensing -
Unit dimensions (width x height x depth)
Kit: 235 x 192 x 85 mm
9.3 x 7.6 x 3.4 inch -
Weight
Kit: 1.5 kg / 3.3 lbs
-
Sampling probe compatibility
Raman Rxn-10 (with bio multi optic)
-
Spectral intensity reference
Calibration Reference Standard
-
Spectral intensity output repeatability (at time of certification)
< ±2 %
-
Long term spectral uncertainty (at any wavelength)
±6.05 %
-
Spectral intensity calibration range
CRS-785: 790.7 to 1074.5 nm
-
Measuring principle
Raman spectroscopy
-
Temperature
Operating:
0 to 40 °C /32 to 104 °F
Storage:
-15 to 50 °C / 5 to 122 °F -
Relative humidity
Storage:
< 80 % Non-Condensing -
Unit dimensions (width x height x depth)
Kit: 235 x 192 x 85 mm
9.3 x 7.6 x 3.4 inch -
Weight
Kit: 1.5 kg / 3.3 lbs
-
Sampling probe compatibility
Raman Rxn-10 (with Raman flow bench)
-
Spectral intensity reference
Calibration Reference Standard
-
Spectral intensity output repeatability (at time of certification)
< ±2 %
-
Long term spectral uncertainty (at any wavelength)
±6.05 %
-
Spectral intensity calibration range
CRS-785: 790.7 to 1074.5 nm
-
Measuring principle
Raman spectroscopy
-
Temperature
Operating:
0 to 40 °C /32 to 104 °F
Storage:
-15 to 50 °C / 5 to 122 °F -
Relative humidity
Storage:
< 80 % Non-Condensing -
Unit dimensions (width x height x depth)
Kit: 235 x 192 x 85 mm
9.3 x 7.6 x 3.4 inch -
Weight
Kit: 1.5 kg / 3.3 lbs
-
Sampling probe compatibility
Raman Rxn-46
-
Spectral intensity reference
Calibration Reference Standard
-
Spectral intensity output repeatability (at time of certification)
< ±2 %
-
Long term spectral uncertainty (at any wavelength)
±6.05 %
-
Spectral intensity calibration range
CRS-785: 790.7 to 1074.5 nm
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .