Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Waterpilot FMX11 - Hydrostatic level measurement

Hydrostatic Level measurement
Waterpilot FMX11

Simple and reliable level probe for freshwater applications

FMX11
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
5-year warranty

Engineered for Confidence

Our Fundamental Selection instruments feature an extended 5-year warranty – a clear testament of our trust in their long-term reliability and performance.

Should a warranty case occur, you can count on a fast replacement process and minimal administrative effort – giving you peace of mind when it matters most and helping you keep your operations running smoothly.

Warranty terms apply

The extended warranty is subject to specific conditions. For full details, please refer to the locally applicable General Terms and Conditions (GTC), which can be found on the respective country page of our website.

Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply voltage

    8...28 VDC

  • Reference Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1 % of URL/year

  • Process temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Ambient temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Measuring cell

    200 mbar...2 bar
    (3 psi...29 psi)

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Material process membrane

    Metal

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply / Communication

    8...28 VDC

  • Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1% of URL/year

  • Ambient temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Process temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Process pressure / max. overpressure limit

    10 bar (145 psi)

  • Pressure measuring range

    200 mbar...2 bar
    (3 psi...29 psi)

  • Main wetted parts

    316L

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Max. measurement distance

    20 m H2O
    (66 ft H2O)

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS