Specs at a glance
-
Accuracy
Standard:
up to 0.05 %
Platinum:
up to 0.025 % -
Process temperature
-40°C...+150°C
(-40°F...+302°F) -
Pressure measuring range
100 mbar...40 bar
(1.5 psi...600 psi) -
Main wetted parts
Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez, Chemraz -
Material process membrane
Ceramic
-
Measuring cell
100 mbar....40 bar
(1.5 psi...600 psi)
Field of application
This transmitter belongs to the new Cerabar generation. The device is robust and can be remotely controlled via app on a tablet using a secure Bluetooth connection. It allows condition based maintenance as well.
The software is designed to simplify the handling. Intuitive wizards guide the user through setup, proof tests and verification of the device.
Heartbeat Technology offers verification and monitoring functions to detect unwanted anomalies e.g. changes in loop characteristics.
Pressure measuring range: up to 40 bar (600 psi)
Fully vacuum resistant up to +150°C (302°F) process temperature
Accuracy: up to +/- 0.025%
Benefits
-
With Heartbeat Technology you are able to verify the health of the device while the process is running.
-
Simple indication of device status - display changes from green to red when diagnostic messages occur
-
Reduce systematic failures - error free SIL commissioning and instrument guided proof testing
-
Wireless control of the device in hard to reach process areas with the SmartBlue App
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Absolute and gauge pressure
-
Characteristic
Premium accuracy pressure transmitter with dry ceramic cell.
Intuitive and clear wizards for commissioning, proof tests and verification. -
Supply voltage
Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC -
Reference Accuracy
Standard:
up to 0.05 %
Platinum:
up to 0.025 % -
Long term stability
0.05 % of URL/ year
0.08 % of URL/ 5 years
0.10 % of URL/ 10 years -
Process temperature
-40°C...+150°C
(-40°F...+302°F) -
Ambient temperature
-40°C...+85°C
(-40°C...+185°F) -
Measuring cell
100 mbar....40 bar
(1.5 psi...600 psi) -
Smallest calibratable span
5 mbar (0.075 psi)
-
Vacuum resistance
0 mbar abs.
-
Max. Turn down
100:1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4" -
Material process membrane
Ceramic
-
Material gasket
FKM, EPDM, HNBR, FFKM
-
Fill fluid
none, dry measuring cell
-
Material housing
Aluminium, 316L
-
Communication
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional) -
Certificates / Approvals
ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
-
Safety approvals
SIL
-
Design approvals
EN10204-3.1
-
Drinking water approvals
NSF, KTW
-
Specialities
Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
-
Measuring principle
Absolute and gauge pressure
-
Characteristic / Application
Premium accuracy pressure transmitter with dry ceramic cell.
Intuitive and clear wizards for commissioning, proof tests and verification. -
Specialities
Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM -
Supply / Communication
Ex d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC -
Accuracy
Standard:
up to 0.05 %
Platinum:
up to 0.025 % -
Long term stability
0.05 % of URL/ year
0.08 % of URL/ 5 years
0.10 % of URL/ 10 years -
Ambient temperature
-40°C...+85°C
(-40°F...+185°F) -
Process temperature
-40°C...+150°C
(-40°F...+302°F) -
Process pressure / max. overpressure limit
60 bar (900 psi)
-
Pressure measuring range
100 mbar...40 bar
(1.5 psi...600 psi) -
Main wetted parts
Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez, Chemraz -
Process connection
Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4" -
Max. measurement distance
400 m (1312 ft) H2O
-
Communication
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional) -
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
-
Drinking water approvals
NSF, KTW
-
Metrological approvals and certificates
MID
-
Options
Touch control display
-
Application limits
Measuring cell: ceramics
If pressurized, possibly
use differential pressure
measurement with two
pressure transmitters
(electronic dp). Observe
ratio head pressure :
hydrostatic pressure
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products