Specs at a glance
Measured variables
Transmittance, opacity, relative opacity, extinction, dust concentration
Measuring range
Transmittance :100 ... 50 % / 100 ... 0 % Opacity: 0 ... + 50 % / 0 ... 100 % Relative opacity: 0 ... + 50 % / 0 ... 100 % Extinction: 0 ... + 0.3 / 0 ... 1 Dust concentration: 0 ... + 200 mg/m³ / 0 ... 10,000 mg/m³ The measurement depends on measuring distance and dust properties
Field of application
The DUSTHUNTER T50 is an economic measuring device for dust at medium to high concentrations in gases above the dew point. Transmittance is the basic measuring value. Opacity and extinction can be calculated and displayed as well as the dust concentration after gravimetric calibration.
Emission monitoring in heating systems
Monitoring of dust concentrations upstream of filter systems
Dust concentration measurements in cement plant
Device properties:
For medium to high dust concentrations
Automated thorough check of zero and reference point
For low to medium measuring distances
Benefits
Easyinstallation, commissioning, and operation
Measurement not dependent on gas velocity, humidity, or particle load
Self-monitoring for low maintenance
Xpert selection
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Success stories
Measuring hydrogen quality in real time
Enapter uses optical analytical measurement technology from Endress+Hauser to determine the purity of hydrogen produced. Find out more!
Read the full story
Measuring principle
Transmittance measurement
Measured variables
Transmittance, opacity, relative opacity, extinction, dust concentration
Measuring range
Transmittance :100 ... 50 % / 100 ... 0 % Opacity: 0 ... + 50 % / 0 ... 100 % Relative opacity: 0 ... + 50 % / 0 ... 100 % Extinction: 0 ... + 0.3 / 0 ... 1 Dust concentration: 0 ... + 200 mg/m³ / 0 ... 10,000 mg/m³ The measurement depends on measuring distance and dust properties
Process pressure
With MCU-P control unit: –50 hPa ... 2 hPa With external purge air unit: –50 hPa ... 30 hPa
Most downloaded
Dust and particle measurement technology
English version - 01/2025
Best in class dust measurement technology with the scattered light and
transmittance dust measuring devices from Endress+Hauser
Language:
English
Version:
01/01/2025
File size:
3 MB
File name:
8030014_CP_Dust_Measuring_Devices_en_V3-0_2025.01.pdf
Emission Monitoring Solutions – broad instrument portfolio and
longstanding experience
English version - 01/2025
An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glance
Language:
English
Version:
01/01/2025
File size:
4.9 MB
File name:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
6 documents
for non-Ex analyzer devices
Language:
English
Version:
01/01/2025
File size:
2.4 MB
File name:
8030257_XA_Safety_Information_non-Ex_ml_V1-0_2016-06_WEB.pdf
Additional Information for Dust Measuring Devices and Combined Probe
Language:
English
Version:
01/01/2025
File size:
2.2 MB
File name:
8030256_AE00_SD_EN_61010_Dust_ml_V1-0_2022-09_EHS.pdf
Dust and particle measurement technology
Best in class dust measurement technology with the scattered light and transmittance dust measuring devices from Endress+Hauser
Language:
English
Version:
01/01/2025
File size:
3 MB
File name:
8030014_CP_Dust_Measuring_Devices_en_V3-0_2025.01.pdf
Soluzioni per il monitoraggio delle
emissioni
Soluzioni per il monitoraggio delle emissioni Ampio portfolio e vasta esperienza
Language:
Italian
Version:
27/05/2025
File size:
4.5 MB
File name:
CP01596C16IT01.25-00.pdf
Emission Monitoring Solutions – broad instrument portfolio and
longstanding experience
An overview brochure about emission monitoring, their measuring principles and technologies, global requirements and services, a selection guide and the measuring devices at a glance
Language:
English
Version:
01/01/2025
File size:
4.9 MB
File name:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
SOPAS device description file for DUSTHUNTER T50
Language:
Language neutral
Version:
05/12/2024
File size:
358 KB
File name:
DUSTHUNTER T50 SDD file
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
FILTER GLASS BRACKET MONT
HOUSING LOWER PART DHT-T00 MOUN.
FOIL REFLECTOR D12 DH-T50 INST.
FOIL REFLECTOR D28 DH-T51 ASSEMBLED
TRIPEL REFLECTOR DH-T52 ASSEMBLED
MOUNTING KIT FLANGE - ANALYZER
DOOR MCU-NWSD/N2SD W.DISPLAY
FILTER CA. 0% TRANSMISSION DH T/C TESTET
FILTER CA.20% TRANSMISSION DH T/C TESTET
FILTER CA.40% TRANSMISSION DH T/C TESTET
FILTER CA.60% TRANSMISSION DH T/C TESTET
FILTER CA.80% TRANSMISSION DH T/C TESTET
FILTER CA.75% TRANSMISSION DH T/C TESTED
FILTER CA.45% TRANSMISSION DH T/C TESTED
FILTER CA.90% TRANSMISSION DH T/C TESTED
FILTER CA.50% TRANSMISSION DH T/C TESTED
FILTER CA.15% TRANSMISSION DH T/C TESTET
FILTER CA.25% TRANSMISSION DH T/C TESTET
FILTER CA.55% TRANSMISSION DH T/C TESTET
SPUELLUFTROHR DH T/SF/C-T/RXX
SCRW,SUNK.CRS-H M 6 10-A2
HOSE DI=50, 90° ELBOW W.MAINTENANCE
O-RING 43 3.5 EPDM70 SH.A BK
CLAMP, TUBE D 20- 32 9 1.4301
SP-SET LOCK FOR WEATHER PROOF COVER
T-MOD RS485,PROFIBUS,PULSE
T-MOD RS485,MODBUS ASCII/RTU,PULSE
FUSE LINKS T2A0 AT POUCH (10PK)
T-MOD ETHERNET V2,MODBUS TCP,PULSE TEST.
T-MOD ETHERNET V2,COLA-B,SERVICE TESTED
T-MOD ETHERNET V1,COLA-B,TRIPLEX,PULSE
CABLE,FEM /FEM SINGLE CONDUC.0,34 0,4M
LINE,FL STEC/BUC 0,30M 80,5 N.LSP
CABLE SCREW CONNECTION SP
AIR FILTER SECONDARYELEMENT CF100
ZEISS CLEANING SPRAY 2X60ML + MCLOTH 18
CLAMP,HOSE D 40- 60 12 SST
RV-BLOWER 115/230V 50/60HZ 1PH 0.37KW
CABLE, MALE/MALE 3M00 USB A/B TR
RV-BLOWER 24VDC/ 2A 110CBM/H 40W
ANALOG IN 2-SIGNAL MODULE
ANALOG OUT 2-SIGNAL MODULE
POW.SUP. 24VDC, 75W, 3,2 A TESTED
CONNECTOR PURGE AIR HOSE DN40
CASE 305285119 WITH INSERT A.DSP
AIR FILTER 3000L/MIN EUROPICLON 100
FILTER INSERT MICRO-TOP 3000L/MIN
PROTECT.CAP D 40 25 LD-PE NC
MODIO-S BASEMODULE W. T.CLAMP
RV-BLOWER 240/415V 50HZ 3PH 1.30KW
UDR-WAECHTER 35MBAR SCHLIES.
SWITCH,LOW PRESSU. 35MBAR NC
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all