Specs at a glance
-
Response time
t50 = 2.5 s
t90 = 5.4 s -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Operating temperature range
Pt100:
-40 °C to 160 °C (-40 °F to 320 °F),
optional up to 190 °C (374 °F)
reference point for automated calibration -
Max. immersion length on request
up to 900.00 mm (35.4'')
Field of application
iTHERM TrustSens is the only self‑calibrating RTD thermometer for hygienic processes, delivering continuous accuracy and compliance without interrupting production. Its fully automated in‑situ self‑calibration and Heartbeat Technology ensure reliable drift detection, audit‑proof documentation, and maximum process efficiency.
Designed for critical hygienic / aseptic applications in the life sciences, food and beverage industry
118 °C (244 °F) calibration point for steam‑based processes, e.g. Sterilization‑In‑Place (SIP).
39 °C (102 °F) calibration point for e.g. Cleaning‑In‑Place (CIP), pasteurization, distillation.
Hygienic- and food safety compliance: EHEDG, ASME BPE, FDA, 3‑A, EC 1935/2004, EC 2023/2006, EU 10/2011.
Instrument approvals: CE/EAC, CRN, CSA, explosion protection e.g ATEX/IECEx.
Benefits
No plant downtime and reduced operational costs: Fully automated in‑situ self‑calibration without interrupting the process for recalibration.
Safe audits and minimized risk: Automatically generated, traceable and audit‑proof calibration certificates.
Improved product quality and process safety: Continuous device monitoring and verification with Heartbeat Technology, including automated loop checks.
Highest measurement accuracy thanks to individual sensor‑transmitter matching performed at the factory.
Easy handling: iTHERM TrustSens comes preconfigured for quick integration; simply connect and start measuring. Guided wizards support intuitive commissioning.
Digitally future‑ready: 24/7 access to all calibration data, including cloud‑based availability via Netilion.
Videos
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
-
Technical Information (TI)
TI iTHERM TrustSens TM371
English version - 07/2025
Metric RTD thermometer with self-calibration technology for hygienic applications
EN 31/07/202531/10/202214/02/202216/06/202114/01/2021Language:
English
Version:
31/07/2025
File size:
1.9 MB
File name:
TI01292TEN_0925-00.pdf
-
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language:
English
Version:
06/12/2024
File size:
1.3 MB
File name:
TI00426FEN_2624.pdf
-
-
-
Technical Information (TI)
TI iTHERM TrustSens TM371
Metric RTD thermometer with self-calibration technology for hygienic applications
EN 31/07/202531/10/202214/02/202216/06/202114/01/2021Language:
English
Version:
31/07/2025
File size:
1.9 MB
File name:
TI01292TEN_0925-00.pdf
-
-
-
Operating Instruction (BA)
BA iTHERM TrustSens TM371
Metric RTD thermometer with self-calibration technology for hygienic applications
EN 31/07/202531/10/202231/03/202220/01/202121/08/2018Language:
English
Version:
31/07/2025
File size:
4.2 MB
File name:
BA01581TEN_0725-00.pdf
-
-
-
Operating Instruction (BA)
BA iTHERM TrustSens Calibration Monitoring
Memograph M RSG45 in connection with iTHERM TrustSens TM371/TM372 and the Field Data Manager (FDM) software
EN 09/06/202515/12/202230/11/2018Language:
English
Version:
09/06/2025
File size:
2.7 MB
File name:
BA01887REN_0325-00.pdf
-
-
-
Short Instruction (KA)
KA iTHERM TrustSens TM371
Metric RTD thermometer with self-calibration technology for hygienic applications
EN 31/07/202519/01/202331/03/202220/01/202123/02/2018Language:
English
Version:
31/07/2025
File size:
1.2 MB
File name:
KA01272TEN_0625-00.pdf
-
-
-
Installation Instructions (EA)
TI Adapter und Flansch EN
TI Adapter und Flansch EN
EN 28/05/2025Language:
English
Version:
28/05/2025
File size:
344.2 KB
File name:
Adapter _Flansche_en.pdf
-
-
-
Installation Instructions (EA)
TI Adapter und Flansch DE
TI Adapter und Flansch DE
EN 28/05/2025Language:
English
Version:
28/05/2025
File size:
348.2 KB
File name:
Adapter_Flansche_de.pdf
-
-
-
Ex Safety Instruction (XA)
CSA Control drawing
CSA Control drawing
Language:
English
Version:
13/05/2022
File size:
326.3 KB
File name:
XA02869T09_EN.pdf
-
-
-
Ex Safety Instruction (XA)
iTHERM TrustSens TM371, TM372
Compact thermometer in metric style for hygienic and aseptic
applications
HART® communication
II1/2G Ex ia IIC T6...T1 Ga/Gb
II1/2D Ех ia IIIC 85 °C…450 °C Da/DbEN 07/03/2022Language:
English
Version:
07/03/2022
File size:
409.6 KB
File name:
XA02834TEN_0122-00.pdf
-
-
-
Special Documentation (SD)
Device viewer
Technical documentation in other languages
Language:
English
Version:
14/07/2021
File size:
478.5 KB
File name:
SD02429R09EN_0121.pdf
-
-
-
Special Documentation (SD)
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411, TT412, TE411, TK40, TMR35, DTT35, TTR35
EN 30/01/202615/09/2023Language:
English
Version:
30/01/2026
File size:
817.3 KB
File name:
SD03119TEN_0226-00.pdf
-
-
-
Case Study (CS)
Automatische Inline-Selbstkalibrierung
Mit der vollautomatischen und rückführbaren Kalibrierung im laufenden
Prozess kann das Risiko von unerkannten Messfehlern auf ein
Minimum reduziert werden.Language:
German
Version:
25/11/2025
File size:
1.4 MB
File name:
CS01577T_20_DE_Lonza_CH_neu.pdf
-
-
-
Case Study (CS)
Automated inline self-calibration at Lonza
Fully automated and traceable calibration during the process can reduce
the risk of undetected measurement errors to a minimumLanguage:
English
Version:
28/02/2019
File size:
1.4 MB
File name:
CS01577T20EN0119_Lonza_SCREEN.pdf
-
-
-
Case Study (CS)
New Belgium Brewing refines calibration process
New Belgium Brewing refines
calibration process
Self-calibrating thermometer
saves 80 hours in calibration timeLanguage:
English
Version:
05/07/2018
File size:
1.5 MB
File name:
CS01573T24EN01.18 - iTHERM TrustSens - New Belgium Brewing.pdf
-
-
-
Case Study (CS)
New Belgium Brewing optimiert Kalibrierprozess
New Belgium Brewing optimiert Kalibrierprozess
Selbstkalibrierendes Thermometer spart enorm AufwandLanguage:
German
Version:
30/01/2019
File size:
504.7 KB
File name:
CS01573T24DE0119 - iTHERM TrustSens_NewBelgiumBrewing.pdf
-
-
-
Innovation (IN)
iTHERM TrustSens TM371, TM372
Il primo termometro al mondo con funzione di autotaratura
Language:
Italian
Version:
02/01/2018
File size:
2.2 MB
File name:
IN01102TIT_0117.pdf
-
-
-
Innovation (IN)
iTHERM TrustSens TM371, TM372
Le premier capteur de température auto-étalonnable au monde
Language:
French
Version:
05/07/2017
File size:
661.1 KB
File name:
IN01102TFR-0117-iTHERM-TrustSens.pdf
-
-
-
Innovation (IN)
iTHERM TrustSens TM371, TM372
Weltweit erstes selbstkalibrierendes Thermometer
Language:
German
Version:
05/08/2022
File size:
2.9 MB
File name:
IN01102TDE_0322.pdf
-
-
-
Innovation (IN)
iTHERM TrustSens TM371, TM372
World’s first self-calibrating thermometer
Language:
English
Version:
05/08/2022
File size:
2.9 MB
File name:
IN01102TEN_0322.pdf
-
-
-
Innovation (IN)
iTHERM TrustSens TM371, TM372
La primera sonda de temperature con autocalibración del mundo
Language:
Spanish
Version:
05/07/2017
File size:
380.7 KB
File name:
IN01102T_Folleto TrustSens_0117_ES.pdf
-