Proline Promag 50P
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag 50P ©Endress+Hauser

The Electromagnetic Flow Measuring Principle

The flowmeter for highest medium temperatures with a modular electronic concept

Promag P is the preferred sensor for applications with highest requirements in a multitude of industries. Combined with the proven Promag 50 transmitter with push buttons, Promag 50P offers highly accurate measurement of liquids for a wide range of applications. Promag 50P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Promag 50P is available as compact or remote version.

  • Benefits

    • Versatile applications – wide variety of wetted materials

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • Maintenance-free – no moving parts

    • Fast commissioning – application-specific Quick Setups

    • Safe operation – display...

  • Field of application

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

    • Dedicated to chemical and process applications with corrosive liquids and high medium temperatures

    Device properties

    • Nominal diameter: max....

Features and specifications

Back

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    The flowmeter for highest medium temperatures with a modular electronic concept. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

    Versatile applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals.

  • Transmitter features

    Fast commissioning – application-specific Quick Setups. Safe operation – display provides easily readable process information. Fully industry compliant – IEC/EN/NAMUR. 2-line backlit display with push buttons. Device as compact or remote version.

  • Nominal diameter range

    DN 15...600
    1/2"...24"

  • Max. measurement error

    ±0.5%
    ±0.2% (optional)

  • Measuring range

    0...9'600 m3/h

  • Max. process pressure

    PN10...40
    Cl 150...300
    JIS 10...20K
    AS 2129 Table E
    AS 4087 PN16

  • Medium temperature range

    -40...+180°C
    (-40...+356°F)

  • Ambient temperature range

    -20...+60°C
    -40...+60°C (optional)

  • Degree of protection

    IP 67 (NEMA 4x)
    IP 68 (Nema 6P)

  • Display/Operation

    Two line display with backlit
    Push button

  • Outputs

    4...20 mA
    Pulse/Frequency
    Status

  • Inputs

    Status

  • Digital communication

    HART
    PROFIBUS PA

  • Hazardous area approvals

    ATEX, IECEx, NEPSI, TIIS, FM, CSA

  • Product safety

    CE, C-tick, EAC marking

  • Pressure approvals and certificates

    PED, CRN

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • F
  • 7
  • B
    • Nr B Order code 50106079

      Kit meas. amplifier PMAG 50 ECC WEA

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039448

      Kit meas. amplifier 50 ECC WEA HE

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106081

      Kit meas. amplifier PMAG 50 ECC SEA

      Language: JA, ID, EN

    • Nr B Order code 71039450

      Kit meas. amplifier 50 ECC SEA HE

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106080

      Kit meas. amplifier PMAG 50 ECC EES

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039449

      Kit meas. amplifier 50 ECC EES HE

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50106076

      Kit meas. amplifier PMAG 50 WEA EX

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039451

      Kit meas. amplifier 50 WEA HE Ex

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106073

      Kit meas. amplifier PMAG 50 WEA

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039445

      Kit meas. amplifier 50 WEA HE

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106078

      Kit meas. amplifier PMAG 50 SEA EX

      Language: JA, ID, EN

    • Nr B Order code 71039453

      Kit meas. amplifier 50 SEA HE Ex

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106075

      Kit meas. amplifier PMAG 50 SEA

      Language: JA, ID, EN

    • Nr B Order code 71039447

      Kit meas. amplifier 50 SEA HE

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106077

      Kit meas. amplifier PMAG 50 EES EX

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039452

      Kit meas. amplifier 50 EES HE Ex

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50106074

      Kit meas. amplifier PMAG 50 EES

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039446

      Kit meas. amplifier 50 EES HE

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

  • C
  • E
  • J
  • 21
  • G
  • 19
  • 18
  • A
    • Nr A Order code 50098018

      Kit connection board D/E/L/P/S/W FS

      Usage: 10/50/51/53/55/400/800

    • Nr A Order code 71039497

      Kit connection board D/E/L/P/S/W FS HE

      Usage: 10/50/53/55 HE = harsh environment

  • 29
  • 30
  • S
    • Nr S Order code 71003946

      Kit S-Dat Promag 50 programmed

      Serialnumber is forceful required

  • 8
  • 9
  • 10
  • 26
    • Nr 26 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 26 Order code 71247838

      Repair kit cover, remote version

      Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease

  • 15
  • 12
  • 14
  • 13
  • 20
  • 11
  • 22
    • Nr 22 Order code 50098020

      Kit parts housing compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W

  • 24
    • Nr 24 Order code 50098019

      Kit parts housing FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W

  • 25
    • Nr 25 Order code 50098023

      Kit housing gasket FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W

  • 23
    • Nr 23 Order code 50098024

      Kit housing gasket compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W

    • Order code DK5CA-

      Promag, cable remote version

      10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable

    • Order code 50XXX-

      Promag 50, transmitter

    • Order code DK5WM-

      Transmitter Promag, mounting set

      10/50/51/53/55/800

    • Order code DK5GC-

      Promag L/W/P/S,E, grounding cable kit

      A kit includes 2 cables

    • Order code DK5GD-

      Promag, grounding disc/protection disc

      Includes 1 grounding disc/protection disc

    • Order code FXA193-

      Serviceinterface FXA193

      The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.

  • Successor