  • Measuring principle

    Electromagnetic

  • Product headline

    Loop-powered volume flow meter for measurement of conductive liquids in standard chemical / process applications, suitable for use in Ex- zones

  • Sensor features

    Intrinsically safe
    S-DAT, T-DAT
    2 Totalizers
    Density function
    Mass calculation

  • Nominal diameter range

    DN 25...200
    1"...8"

  • Max. measurement error

    ±0.5%

  • Measuring range

    0...1100 m3/h

  • Max. process pressure

    PN10...40
    Cl 150...300
    JIS 10...20 K

  • Medium temperature range

    -40...+180°C
    (-40...+360°F)

  • Ambient temperature range

    -20...+60°C

  • Degree of protection

    IP 67 (NEMA 4x)

  • Display/Operation

    Four line display
    Touch control

  • Outputs

    4...20 mA + pulse-/frequency-/status (configurable)

  • Digital communication

    HART

  • Hazardous area approvals

    ATEX
    FM
    CSA

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • 2
  • 5
  • 10
  • 9
    • Nr 9 Order code 50097147

      Kit Ground terminal/Cover clamp

      10/1YH/23/65/72/73/91W/92F/8FF/8FE/8CM

  • 13
    • Nr 13 Order code 50098020

      Kit parts housing compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W

  • 12
    • Nr 12 Order code 50098024

      Kit housing gasket compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W

    • Order code DK5GC-

      Promag L/W/P/S,E, grounding cable kit

      A kit includes 2 cables

    • Order code DK5GD-

      Promag, grounding disc/protection disc

      Includes 1 grounding disc/protection disc

    • Order code FXA193-

      Serviceinterface FXA193

      The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.

  • Successor