This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

"Product Phased Out".
Level, radar, guided.
Hygienic.
Application: liquids.
Factory precalibrated.
Incl. Setup-/diagnostic software.
:: Reliable measuring:
in case of moved surface + foam,
for changing medias.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Guided radar
-
Characteristic / Application
Rod probe:
not affected by spray ball operation
Probes electro-polished or mechanically polished -
Specialities
Pharma Certificate of Compliance
-
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
-
Accuracy
Rod probe: +/-3 mm (0.13")
-
Ambient temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F) -
Process temperature
-20 °C ... 150 °C
(-4 °F ... 302 °F) -
Process pressure absolute / max. overpressure limit
Vaccum ... 16 bar
-
Main wetted parts
316L/1.4435
PEEK (USP Cl. VI)
EPDM / KALREZ (USP Cl. VI) -
Process connection
Flange: ASME B16.5 1 1/2", 2"
-
Process connection hygienic
Tri-Clamp ISO2852
DIN11851
SMS
DIN11864
NEUMO Biocontrol -
Sensor length
Rod: 4 m (178")
-
Max. measurement distance
Rod probe :
4 m (178") Min. DK > 1.6 -
Communication
4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX
FM
CSA
SIL
EHEDG, 3A -
Options
Calibration Kit
-
Successor
FMP53