Proline Prosonic Flow
B 200 Ultrasonic flowmeter
The device for accurate, reliable biogas measurement with loop-powered technology
Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of gas flow as well as gas quality. In addition to efficient process control and energy balancing, Heartbeat Technology ensures compliance and process safety at all times.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s) -
Measuring range
Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s) -
Medium temperature range
0 to +80 °C (+32 to +176 °F)
-
Max. process pressure
11 bar a (159 psi a)
-
Wetted materials
Sensor: 1.4404/1.4435 (316L)
Transducer: HNBR
Temperature sensor (option): AFM 34
-
Quick selection
Individual configuration
-
Benefits
Integrated real-time methane fraction measurement
Optimized for low pressure gas – specialized sensor design
No additional pressure loss – full bore design
Process transparency – diagnostic capability
Convenient device wiring – separate connection compartment
Safe operation – no need to open the device due to...
-
Field of application
The measuring principle is unaffected by gas composition
Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.
Device properties:
Multivariable device: flow, temperature and methane
Medium temperature: 0 to 80...
Documents / Manuals / Software
-
Proline Prosonic Flow B 200
Technical Information
Ultrasonic transit time flowmeter
Technical Information (TI) -
Proline Prosonic Flow B 200
HART
Operating Instructions
Ultrasonic transit time flowmeter
Operating Instruction (BA) -
Proline Prosonic Flow 200
HART
Description of Device Parameters
Ultrasonic time-of-flight flowmeter
Device Parameter (GP) -
Proline Prosonic Flow B 200
Brief Operating Instructions
Ultrasonic time-of-flight flowmeter
Short Instruction (KA)10/15English -
Transmitter electronics FHX50
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Cover
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Sealing set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50Installation Instructions (EA) -
Replacing cable harness, cable gland
Installation Instructions
Prosonic Flow B 200
Installation Instructions (EA) -
I/O module
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promass 200/TB2, Prosonic Flow B 200, Promag 200
Installation Instructions (EA) -
Replacing sensor, gasket for sensor, cleaning the sensor connection
piece with brush
Installation Instructions
Prosonic Flow B 200
Installation Instructions (EA) -
Set housing security clamp
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Replacing the I/O-Module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200
Installation Instructions (EA) -
Replacing the display module
Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50Installation Instructions (EA) -
Replacing the main electronics module
Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200
Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Housing filter
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Terminal set
Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,Installation Instructions (EA) -
Proline Prosonic Flow 200
INMETRO:
Ex d[ia] IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Prosonic Flow B 200
Cl. I Div. 1, Zone 0 for IS
(Ex i Intrinsically safe version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prosonic Flow B 200
NEPSI:
Zone 1
Ex d version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prosonic Flow B 200
ATEX: II2G
IECEx: Zone 1
Ex i version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Prosonic Flow B 200
ATEX: II2G
IECEx: Zone 1
Ex d version
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Prosonic Flow B 200
Cl. I Div. 1, Zone 1 for XP
(Ex d Flameproofed version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prosonic Flow B 200
NEPSI:
Zone 1
Ex i version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Prosonic Flow 200
INMETRO:
Ex ia IIC T6…T1
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Prosonic Flow B 200
Heartbeat Technology Application Package
Special Documentation
Ultrasonic transit time flowmeter
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Prosonic Flow 200
Information on the Pressure Equipment Directive
Special Documentation
Ultrasonic transit time flowmeter
Special Documentation (SD) -
Levelflex FMP5x, Micropilot FMR5x
Weather protection cover
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Prosonic Flow B 200
Manufacturer information regarding
firmware updates
(NE 53)
New firmware version:
Prosonic Flow B 200 HART: 1.02.01Manufacturer Information (MI) -
Trait d'union 56 - Edition Eau et Environnement
Le Journal d'Information Endress+Hauser France
Customer Magazine (CM)06/13fr -
Nowe możliwości w zakresie pomiaru
przepływu i analizy biogazu- artykuł CE_02_2012
Przepływomierz ultradźwiękowy Prosonic Flow B200, który w zakresie
pomiaru ilości i analizy biogazu oferuje zupełnie nowe możliwości.
Ciągłe monitorowanie wielu parametrów procesu: składu gazu, ciśnienia,
temperatury, a przede wszystkim ilości produkowanego biogazu.
Pomiar przepływu biogazu, pomiar stężenia metanu.Publications (PU)03/12Polish -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10English -
Proline Prosonic Flow B 200
American Version
For reliable biogas flow measurement without compromisesInnovations (IN)09/17English -
Proline Prosonic Flow B 200
American Version
For reliable biogas flow measurement without compromisesInnovations (IN)05/12English -
Proline Prosonic Flow B 200
Pro spolehlivé a neomezené měření průtoku bioplynu
Innovations (IN)04/14Czech -
Proline Prosonic Flow B 200
Für die zuverlässige Biogas-Durchflussmessung ohne Kompromisse
Prozessüberwachung leicht gemachtInnovations (IN)04/14German -
Proline Prosonic Flow B 200
For reliable biogas flow measurement without compromises
Process monitoring made easyInnovations (IN)04/14English -
Folleto Proline Prosonic Flow B 200
Para medidas fiables del caudal de biogás
Innovations (IN)02/12Spanish -
Proline Prosonic Flow B 200
Pour une mesure fiable et sans compromis du débit de biogaz
La surveillance de process et le bilan énergétique simplifiés
Innovations (IN)02/12fr -
Proline Prosonic Flow B 200
Pour une mesure fiable et sans compromis du débit de biogaz
Innovations (IN)02/12fr -
Proline Prosonic Flow B 200
Misure affidabili della portata del biogas, senza compromessi.
Innovations (IN)01/13Italian -
Proline Prosonic Flow B 200
Niezawodny pomiar przepływu biogazu bez żadnych kompromisów
Innovations (IN)01/12Polish -
Prosonic Flow B200
Ultraschall-Durchflussmessgerät für Gase (Biogas, Faulgas und
Deponiegas) zur
kontinuierlichen Erfassung des (Norm-)Volumenfluss sowie optional
Methananteil und
TemperaturTender Text06/20German -
EDD Single, PDM_HART_FL_ProsonicFlowB200_0x005A_0x02_0x01, 31.03.2014 (Fl
ow, Prosonic Flow B 200, 0
HART,
PDM Version: 6.1, 8.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_ProsonicFlowB200_0x115A_0x01_0x01, 31.03.2014 (Fl
ow, Prosonic Flow B 200, 0
HART,
Field Device Manager Version: R410Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_ProsonicFlowB200_0x005A_0x02_0x01, 21.08.2019 (Flow, Prosonic Flow B 200,
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_ProsonicFlowB200_0x005A_0x03_0x01, 21.08.2019 (Flow, Prosonic Flow B 200,
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlowB200_0x005A_0x03_0x01, 02.11.2015 (Flow, Prosonic Flow B 200)
HART,
PDM Version: 6.1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_ProsonicFlowB200_0x005A_0x02_0x01, 21.08.2019 (Flow, Prosonic Flow B 200,
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_ProsonicFlowB200_0x005A_0x03_0x01, 21.08.2019 (Flow, Prosonic Flow B 200,
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_ProsonicFlowB200_0x005A_0x03_0x01, 27.10.2015 (Flow, Prosonic Flow B 200)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_ProsonicFlowB200_0x005A_0x01_0x01, 21.08.2019 (Flow, Prosonic Flow B 200,
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlowB200_0x115A_0x01_0x01, 31.03.2014 (Flow, Prosonic Flow B 200, 0
HART,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_ProsonicFlowB200_0x005A_0x01_0x01, 21.08.2019 (Flow, Prosonic Flow B 200,
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicFlow_B200_9B2B_HART_FW_1_02_zz_Dev_Rev_3, 06.11.2020 (Flow, Prosonic Flow B 200
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.6.0.800Language neutral -
DTM Single, ProsonicFlowB200_9B2Bxx_HART_FW1_01_zz_Dev_Rev_2, 26.10.2020 (Flow, Prosonic Flow B 200
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.0.0.669Language neutral -
DTM Single, ProsonicFlowB200_9B2Bxx_HART_FW1_00_zz_Dev_Rev_1, 26.10.2020 (Flow, Prosonic Flow B 200
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.599Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_ProsonicFlowB200_0x005A_0x03_0x01, 03.11.2015 (Flow, Prosonic Flow B
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_ProsonicFlowB200_0x5A_0x01_0x01, 31.03.2014
(Flow, Prosonic Flow B 20
HART,
Plant Resource Manager Version: R3.05Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_ProsonicFlowB200_0x005A_0x02_0x01, 31.03.20
14 (Flow, Prosonic Flow B
HART,
Plant Resource Manager Version: R3.05Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Prosonic Flow B
Product Code: 9B2B-
Declaration Number: EC_00302_03.16EU DeclarationGerman , English , fr -
Prosonic Flow B
Product Code: 9B2B-
Declaration Number: EC_00303_02.16EU DeclarationGerman , English , fr -
Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow B
Product Code: 92F-, 9B2B-, O9B2B-
Declaration Number: EC_00056_03.15EU DeclarationGerman , English , fr -
t-mass T, Prowirl R, Prowirl O, Prowirl F, T-MASS I, T-MASS F, t-mass B, t-mass A, t-mass, Prowirl D, PROSONIC FLOW P, Prosonic Flow G, PROSONIC FLOW E, Prosonic Flow 93, Prosonic Flow B, Prosonic Flow 92, Prosonic Flow 91, PICOMAG, Magphant, Dosimass, Promass 40, Promag D
Product Code: 92F-, ODMA-, 7R2B-, 7F2B-, 93P-, 93W-, 7O2B-, 7D2B-, 7O2C-, 7F2C-, 7R2C-, 65I-, 93C-, 7D2C-, 65F-, 93TA1-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9P5B-, DMA-, DTI200-, DTT31-, DTT35-, DTT35L-, DTT31L-, 91W-, 8E-, 6TAB-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 5D4C-, 40E-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EACE N RU-D.CH.AD07.B.02246/20MiscellaneousRussian -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex d [ia]Explosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex d [ia], Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/T6...T1
Protection: NIExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1
Protection: Ex iaExplosion ProtectionPortuguese -
Prosonic Flow B
Product Code: 9B2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1
Protection: Ex d [ia]Explosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1, I/zone 1
Protection: XP/ISExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1
Protection: Ex d [ia]Explosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D/T6...T1, I/zone 0
Protection: ISExplosion ProtectionEnglish -
Prowirl R, Prowirl O, Prowirl F, Prowirl D, Prowirl C, Prosonic Flow B, Promass F, Promass E, Promass A, Promag P, Promag H, Promag E
Product Code: O9B2B-, O5P2B-, O5H2B-, 9B2B-, 8F2B-, 8E2C-, 8E2B-, 8A2B-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 7C2B-, 5P2B-, 5H2B-, 5E2B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: South Africa
Approval Agency: MTEx
Category: zone 1
Protection: Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 G
Protection: Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: Japan
Approval Agency: CML
Protection: Ex d [ia]Explosion ProtectionJapanese -
Prosonic Flow B
Product Code: 9B2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1
Protection: Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 G
Protection: Ex d [ia]Explosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex d [ia] IIC T6...T1 Gb, Ex ia IIC T6...T1 GbExplosion ProtectionEnglish -
Promass A, Promass E, Promass F, Prosonic Flow B
Product Code: 8A2B-, 8E2B-, 8E2C-, 8F2B-, 9B2B-, O9B2B-
Region/Country:
Approval Agency:
Protection: Ex ia, Ex ic, Ex nA, Ex tb, Ex ec, Ex dbExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1
Protection: Ex d [ia]Explosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-, O9B2B-
Region/Country: South Africa
Approval Agency: SABS
Category: zone 1
Protection: Ex d [ia], Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1
Protection: Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1
Protection: Ex iaExplosion ProtectionEnglish -
Prosonic Flow B
Product Code: 9B2B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: DEVICE REV. 3, HART 7Fieldbus ConformanceEnglish -
Prosonic Flow 91, Prosonic Flow B
Product Code: 91W-, 9B2B-
Region/Country:
Approval Agency: MSST
Approval Number: MSST_2247MetrologyRussian
Accessories / Spare parts
-
-
Nr 34 Order code 71108602
I/O module Flow, 2-wr. 2x4-20mA,HART, Ex
Non-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: FTM50/FTM51/FTM52. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
-
-
Order code 71128617
Overvoltage protection (OVP10),1-Channel
4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71128619
Overvoltage protection (OVP20),2-Channel
4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 71197334
Transmitter electronics FHX50
Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.
-
Order code
Remote display FHX50 please order with separate order structure.
-
Order code 71296840
Plug M12, VA
To connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.
-
-
-
Nr 30 Order code XPD0002-
-
-
-
Order code 71206552
-
Order code 71206554
-
Order code 71206555
-
-
-
Nr 34 Order code XPD0015-
-
-
-
Order code 71206556
-
-
-
Nr 37 Order code 71110280
Terminal set 2-wire, I/O module
Consists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 34 Order code XPD0016-
I/O module, 2-wire, 4-20mA,HART, PFS, Ex
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.
-
Nr 34 Order code XPD0018-
I/O,2-wire,4-20mA,HART,PFS,4-20mA input
Non-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output. 1x current input.
-
-
-
Nr 40 Order code XPD0024-
Display module, SD02, push buttons
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.
-
Nr 40 Order code XPD0025-
Display module, SD03, Touch Control
For housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.
-
-
-
Nr 20 Order code 71110281
Cover GT18 316L, HNBR
Material: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 20 Order code 71110282
Cover GT18 316L, sight glass, HNBR
Material: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110291
Cover GT18 316L, terminal Ex, HNBR
Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 25 Order code 71110284
Cover GT18 316L, terminal Ex d, HNBR
Material: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 25 Order code 71185516
Cover GT18 316L, Terminal, OVP, HNBR
Material: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200.
-
-
-
Nr 20 Order code 71110299
Cover GT20 Alu, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 20 Order code 71110297
Cover GT20 Alu, sight glass, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 25 Order code 71110301
Cover GT20 Alu, Terminal Ex, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71110302
Cover GT20 Alu, Terminal Ex d, HNBR
Material: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Nr 25 Order code 71185517
Cover GT20 Alu, Terminal, OVP, HNBR
Material: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71115505
Kit 10 ext. M20x1,5/G 1/2" (plug brass)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71115509
Kit 10 ext. M20x1,5/NPT1/2"(plug brass)
-
-
-
Nr 65 Order code 71110303
Sealing set GT18/GT19/GT20, EPDM, HNBR
Consists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 19 Order code 71115174
Housing filter 316L, GT18, 1 set
Consists of: 2x filter plug metall 316L. 1x pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.
-
Nr 19 Order code 71115175
Housing filter Brass/Ni GT19/20, 1 set
Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Nr 17 Order code 71115176
Set housing securing clamps
Usage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
-
-
Order code 71162242
Weather prot. cover GT18/GT19/GT20, 316L
Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/ FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.
-
Order code 9B2BXX-
Transmitter Prosonic Flow B 200, 9B2BXX
-
-
-
Nr 53 Order code XPD0003-
-
-
-
Nr 51 Order code XPD0004-
US Transducer, tools, Prosonic Flow B
Ultrasonic transducer Sensor seal Hot swap tool
-
-
-
Order code DK7ST-
-
Order code XPRFID-
-