iTHERM TrustSens TM371
Self-calibrating temperature sensor

iTHERM TrustSens TM371 Hygienic compact thermometer with self-calibrating function ©Endress+Hauser
Winner of the HERMES AWARD 2018 Deutsche Messe AG
iTHERM TrustSens TM371 Hygienic compact thermometer with self-calibrating function ©Endress+Hauser

iTHERM TrustSens - 100% Compliance – 0% Effort

iTHERM TrustSens TM371 self-calibrating hygienic compact thermometer with iTHERM QuickNeck ©Endress+Hauser

iTHERM TrustSens - innovative thermometer designed for food & beverage and life sciences industries

iTHERM TrustSens TM371 self-calibrating hygienic compact thermometer for higher product safety ©Endress+Hauser

iTHERM TrustSens - The award-winning thermometer for all hygienic and aseptic applications

100% compliance, 0% effort Hygienic compact RTD thermometer

The award-winning smart temperature probe with integrated HART® transmitter and Heartbeat Technology features the world’s first RTD sensor unit capable of fully automated in-situ self-calibration. It effectively eliminates the risk of undetected non-conformities, reduces production downtime and increases product safety and process efficiency in applications of the food & beverage and life sciences industries. The device is fully compliant to FDA 21 CFR Part 11 regulations and GMP rules.

  • Benefits

    • Risk and cost reduction thanks to self-calibration and Heartbeat Technology

    • No production downtime due to an automated and fully traceable inline self-calibration

    • Automatized documentation, memory for 350 calibration points

    • Printable calibration...

  • Field of application

    • Specially designed for use in hygienic and aseptic applications in the food & beverage and life sciences industries

    • Measuring range: –40 to 160 °C (–40 to 320 °F)

    • Pressure range up to 50 bar (725 psi)

    • Protection class IP67/68 or IP69K

    • Communication:...

Features and specifications

Back

Details

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    self-calibrating

    metric style

    compact temperature probe

    hygienic design

    hygienic process connection

  • Thermowell / protection tube

    without

    incl. thermowell

    incl. T-/ellbow thermowell

  • Insert / probe

    pipe version, isolated wires, not flexible

  • Outer diameter protection tube / Insert

    6,0 mm (0,24'')

    9,0 mm (0,35'')

    12,7 mm (0,5")

  • Max. immersion length on request

    up to 900,00 mm (35,4'')

  • Material protection tube/ thermowell

    1.4435 Delta-Ferrit < 1%

    316L

  • Process connection

    compression fitting

    weld in adapter

    clamp connections acc. to ISO2852

    screwed pipe joint acc. to DIN 11851

    aseptic screwed pipe joint acc. to DIN 11864-1

    metallic sealing system

    thread acc. to ISO 228 for liquiphant adaptor

    APV Inline

    Varivent

    Ingold

    SMS 1147

    Neumo Biocontrol

    T- and corner pieces

  • Tip shape

    straight

    reduced

  • Surface roughness Ra

    0,76 μm (29,92 μin)

    0,38 μm (14,96 μin)

    0,38 μm (14,96 μin) electropolished

  • Operating temperature range

    PT 100:

    -40 °C …160 °C

    (-40 °F …320 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Response time

    t50 = 2,5 s

    t90 =9,5s

  • Integration head transmitter

    no (4…20mA Signal, HART)

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
    • Order code 60022519

      plug screw fitting G1/2 1.4435

    • Order code 71405560

      Weld in adapter M12x1.5 1.4435/316L

    • Order code 71424800

      G1/2 metal to metal weld in adapter

      for connection with G1/2" female thread. Material 316L/1.4435. 2x leakage bore.

    • Order code 60017887

      Adapter for Ingold connection

    • Order code 60018911

      O-ring set for ingold connection

      set includes 5 gaskets

    • Order code 52018765

      Weld-in adapter G3/4 d=50, 316L, 3.1

      Flush mount process connection Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51, FTI51, FTL20/FTL20H, FTL31/FTL33, FTW23/FTW33, 11371. Usage: TMR35.

    • Order code 52028295

      Weld-in adapter G3/4, d=29, 316L, 3.1

      Flush mount process connection. For pipe-mounting. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23/FTW33.

    • Order code 52021717

      O-ring 14.9x2.7 VMQ, FDA, 5 pcs.

      Material: silicone VMQ 75. Usage: Weld-in adapter G3/4, 316L, (71258355) vesselmounting, (71258357) pipe-mounting, flush mount, FTL31/FTL33, FTW23/FTW33, QMW43, Weld-in adapter G3/4, 316L, 3.1, (52018765) vesselmounting, (52028295) pipe-mounting, flush mount, FMI51, FTI51, FTL31/FTL33, FTW23/FTW33, QMW43.

    • Order code 52001052

      Weld-in adapter G3/4, d=55, 316L

      Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FTL50/FTL50H, FTL80. Usage: TMR35.

    • Order code 52011897

      Weld-in adapter G3/4, 316L, 3.1

      Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FTL50/FTL50H, FTL80. Usage: TMR35.

    • Order code 52014473

      O-ring 21.89x2.62 VMQ, FDA, 5 pcs.

      Material: silicone VMQ 70. Usage: weld-in adapter G3/4, 316L (52001052) flush mount, 316L, 3.1 (52011897) flush mount, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81.

    • Order code 71093129

      Weld-in adapter G1, d=53, 316L, 3.1

      Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material Seal: silicone O-ring FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTL330H/FTL330L, FTW23, FTW33, PMP135, PTP35.

    • Order code 52014472

      O-ring 28.17x3.53 VMQ, FDA, 5 pcs.

      Material: silicone VMQ 70. Usage: weld-in adapter G1, 316L, (52001051) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81, QMW43, Weld-in adapter G1, 316L, 3.1, (52011896) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81,QMW43, sliding sleeve FTM21.

    • Order code 52001051

      Weld-in adapter G1, d=60, 316L

      Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35. Usage: TM401/TM411, TMR35.

    • Order code 52011896

      Weld-in adapter G1, d=60, 316L, 3.1

      Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35. Usage: TM401/TM411, TMR35.

    • Order code 52014472

      O-ring 28.17x3.53 VMQ, FDA, 5 pcs.

      Material: silicone VMQ 70. Usage: weld-in adapter G1, 316L, (52001051) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81, QMW43, Weld-in adapter G1, 316L, 3.1, (52011896) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81,QMW43, sliding sleeve FTM21.

    • Order code 52001221

      Weld-in adapter G1, adjustable, 316L

      Flush mount process connection. Material: 316L. Liquiphant is adjustable. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL330H/330L.

    • Order code 52011898

      Weld-in adapter G1, adjustable,316L, 3.1

      Flush mount process connection. Material: 316L. Liquiphant is adjustable. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FTL20/FTL20H, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL31/FTL33, FTL80/FTL81, FTL330H/FTL330L.

    • Order code 52014424

      Profile gasket 29x36x3.7, FDA, 5 pcs.

      Material: silicone VMQ. Usage: Process connect. G1 flush mount, Weld-in adapter G1, 316L, adjustable (52001221), Weld-in adapter G1, 316L, 3.1, adjustable (52011898), FTL31/FTL33, FTL80/FTL81, FTL50/FTL50H/FTL51/FTL51H, Weld-in adapter Rd52, 316L, adjustable, (52001047), 316L, 3.1, adjustable, (52006909), FTL33, FTL50/FTL50H/FTL51/FTL51H.

    • Order code 71275424

      Grip cap flexible yellow TPE

    • Order code 71215757

      Spare Part Kit Press-Screw TK40 G1/4 d6

    • Order code 71217633

      Spare Part Kit Press-Screw TK40 G1/2 d6

    • Order code 51516983

      Commubox FXA291 (Hardware)

      Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate).

    • Order code 71217708

      Cordset 4p D18 IP69K

      PVC cable, 4 x 0.34 mm2 (22 AWG) with M12x1 coupling nut from stainless steel; straight female connector type; screw plug; length 5 m (16.4 ft); IP69K.

    • Order code 71387767

      Cabel Connektor M12 IP69k 5m

    • Order code 71392158

      Adapto Upgrade TXU10 - TM37x

    • Order code TK40-

      iTHERM TK40 Compression Fitting

      Weld-in compression fitting with hygienic design. For applications in the food/ beverages and pharmaceutical industries.

    • Order code XPT0001-

      Spare Part Kit Sealing for TK40 XPT0001

      delivery: 5 parts per kit

    • Order code TT411-

      iTHERM TT411 Thermowell

      Thermowell with hygienic design. Metrical version for applications in the food/beverages and pharmaceutical industries.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code SFE500-

      FieldCare

      FieldCare is a Software tool based on FDT/DTM technology. FieldCare is scalable which allows to fulfill tasks from Device Setup to Plant Asset Management. FieldCare includes tested and approved Endress+Hauser and third party DTMs and may be combined with other Endress+Hauser products like Condition Monitoring or W@M. Additional hardware (e.g. modems, cable) is needed. A software support service including updates to guarantee top quality and perfomance is recommended.

    • Order code FXA42-

      Fieldgate FXA42

      Compact gateway for data capture of field devices, without antenna. Embedded web server, alarm / event handling. Application: remote monitoring, inventroy data monitoring, web enabled field interface. Field device interfaces 4-20mA, Modbus RTU, digital inputs/outputs. :: Meets NAMUR NE43 requirements. :: Data transition into SupplyCare.

    • Order code TM371-

      TrustSens TM371

      Self-calibrating thermometer with optional thermowell for applications in the food/beverages and pharmaceutical industries. 100% compliance by 0% effort. Measuring range: -40...+160oC/ -40...+320oF ::Risk reduction and cost reduction through a fully automated inline self-calibration. ::Fully automatized and audit-proof documentation. ::No risk of undetected failures through Heartbeat monitoring.