Specs at a glance
-
Accuracy
class 1 acc. to IEC 60584
-
Response time
depending on configuration
t50 = 3 s
t90 = 7 s -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
-
Operating temperature range
Type K:
-40 °C ...1.100 °C
(-40 °F ...2.012 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F) -
Max. immersion length on request
up to 30.000,00 mm (1.181,10'')
Field of application
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. The sensor is designed for use in a separate thermowell. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The modular design with a variety of options can be adapted to the measurement task.
Heavy duty applications
Oil & Gas processing industry
Measuring range: –40 to 1 100 °C (–40 to 2 012 °F)
Protection class: IP68
Benefits
Types of protection for use in hazardous locations: Intrinsic safety (Ex ia), flameproof (Ex d), non-sparking (Ex nA)
High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
High degree of insert compatibility and design as per DIN 43772
Extension neck, nipple union version, to protect the head transmitter from overheating
Predecessor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Thermocouple
-
Characteristic / Application
US style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
with neck
to use with thermowell -
Thermowell / protection tube
to use with thermowell
-
Insert / probe
replaceable (without process interruption)
-
Outer diameter protection tube / Insert
Insert Diameter
6,0 mm (0,24'') -
Max. immersion length on request
up to 30.000,00 mm (1.181,10'')
-
Material protection tube/ thermowell
Not defined
-
Optional coating
Not defined
-
Process connection
male thread:
NPT1/2" -
Tip shape
straight
-
Surface roughness Ra
0,8 μm (31,5 μin.)
-
Operating temperature range
Type K:
-40 °C ...1.100 °C
(-40 °F ...2.012 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F) -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
-
Accuracy
class 1 acc. to IEC 60584
-
Response time
depending on configuration
t50 = 3 s
t90 = 7 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
ATEX II
IECEx
NEPSI
EAC Ex
Explosion proof -
Certification
Gost Metrology
SIL (transmitter only)
Configure to download the CAD drawings of this product
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products